Fire sprinkler inspection and testing
NFPA 25 is the national standard that state fire codes, such as Utah's and Minnesota's, adopt for sprinkler inspection, testing and maintenance, and it makes the building owner responsible. Dry system gauges are checked weekly, control valves and wet system gauges monthly, alarm devices and fire department connections quarterly, and sprinklers, pipe and the main drain yearly. Dry systems add a full trip test every 3 years, and gauges, check valves and pipe interiors come due every 5 years.
What to know
Licensed companies for fire sprinkler inspection
All Test Fire Protection LLC
100/100Alarm Detection Systems INC
100/100Elyon Fire & Life Safety LLC
100/100Reliable Fire Protection
100/100Getz Fire Equipment Co
100/100Fox Valley Fire & Safety Co, INC
100/1001ST Fire Safety, LLC
100/100Zion Fire Protection LLC
100/100Eagle One Fire Systems LLC
100/100Complete Fire Protection, LLC
100/100By state
- Arkansas: 93 licensed offices
- Oklahoma: no fire sprinkler inspection class on the state's list
- Washington: 125 licensed offices
- Illinois: 201 licensed offices
- Idaho: 76 licensed offices
- New Jersey: 267 licensed offices
- Alabama: 142 licensed offices
- Nebraska: 49 licensed offices
- Utah: no fire sprinkler inspection class on the state's list
- Maryland: 151 licensed offices
- New York: no fire sprinkler inspection class on the state's list
- New Mexico: 70 licensed offices
- Texas: 416 licensed offices
- Connecticut: 30 licensed offices
- California: 2096 licensed offices
How often inspectors cite sprinkler inspection, testing and maintenance
- US nursing homes cited for sprinkler inspection, testing and maintenance (K353), Sep 2023 to Aug 2026
- 8,069 of 14,338 inspected homes (56%)
- Citations of this item
- 11,472 in 30,293 standard inspections
- Rank among all CMS fire safety items, by homes cited
- #1
- CMS tag text
- K353: Inspect, test, and maintain automatic sprinkler systems.
- Washington94% of 193
- Maryland83% of 214
- California82% of 1,162
- New Mexico70% of 67
- New Jersey64% of 347
- Alabama62% of 65
- Illinois55% of 666
- Texas53% of 1,176
- New York50% of 578
- Nebraska48% of 180
- Idaho45% of 78
- Connecticut43% of 188
- Oklahoma30% of 282
- Arkansas24% of 221
- Utah12% of 97
- United States56% of 14,338
- How counted
- CMS Life Safety Code tags at standard inspections, Sep 2023 to Aug 2026; a home counts once; no home is named
- Nursing home fire safety citations: CMS Fire Safety Deficiencies, release September 30, 2026, downloaded October 8, 2026.
- Inspection dates: CMS Inspection Dates, release September 30, 2026.
- Arkansas2020 (exam only)
- Oklahomanot named
- Washingtonnot named
- Illinoisnot named
- Idaho2020
- Alabamanot named
- Nebraska2011 (exam only)
- Utah2023
- Marylandnot named
- New Yorknot named
- New Mexiconot named
- Texas2020
- Connecticutnot named
- Californianot named
Darker dot: adopted or in licensing rules. Lighter: guidance or exam only. Sources on each state page.
Questions
How often do fire sprinklers need to be inspected under NFPA 25?
Parts of the system are checked weekly, monthly or quarterly, and the sprinklers, pipe, hangers and main drain are inspected or tested every year. Dry systems also get a full trip test every 3 years, and gauges, check valves and pipe interiors are due every 5 years.
Does a fire sprinkler backflow preventer need testing?
Yes. Springdale, Arkansas requires a test within 10 days of installation and every year after, and San Antonio requires annual testing too.
How often is a fire pump tested?
Often weekly, plus a flow test once a year, though the schedule depends on the code your area adopted. Alabama's public health form lists weekly fire pump inspections, and Clark County, Nevada requires the annual flow test results.
What does a fire marshal inspection or permit cost?
City fire marshal inspection and permit fees run from $50 to $250 across 24 published prices. For a kitchen hood or fire alarm inspection, ask a company for a written quote per system.
Never miss your annual fire inspection
Fire extinguishers need maintenance by a licensed company every year (OSHA 29 CFR 1910.157), and sprinkler, alarm and kitchen hood systems have their own schedules. Enter the dates on your last tags and save each next due date to your own calendar, with a reminder before it.
Free. A calendar file you keep; nothing is sent to us. Your fire marshal's notice or your state's adopted code sets the exact dates.