Fire extinguisher inspection and service
OSHA 29 CFR 1910.157 requires portable fire extinguishers to be visually inspected monthly.
What to know
Licensed companies for fire extinguisher inspection
Certified Fire & Security
100/100All Test Fire Protection LLC
100/100Elyon Fire & Life Safety LLC
100/100Reliable Fire Protection
100/1001ST Fire Safety, LLC
100/100Zion Fire Protection LLC
100/100Eagle One Fire Systems LLC
100/100Castle Sprinkler & Alarm, Inc.
100/100State Fire DC Specialties
100/100By state
- Arkansas: 86 licensed offices
- Oklahoma: 107 licensed offices
- Washington: no fire extinguisher inspection class on the state's list
- Illinois: no fire extinguisher inspection class on the state's list
- Idaho: no fire extinguisher inspection class on the state's list
- New Jersey: 208 licensed offices
- Alabama: no fire extinguisher inspection class on the state's list
- Nebraska: no fire extinguisher inspection class on the state's list
- Utah: 142 licensed offices
- Maryland: 163 licensed offices
- New York: 62 licensed offices
- New Mexico: 108 licensed offices
- Texas: 843 licensed offices
- Connecticut: no fire extinguisher inspection class on the state's list
- California: no fire extinguisher inspection class on the state's list
Is my extinguisher due?
| Type (as OSHA names it) | Hydrostatic test | Examined inside |
|---|---|---|
| Dry chemical, stored pressure, mild steel, brazed brass or aluminum shell | every 12 years | Emptied and maintained every 6 years (OSHA) |
| Dry chemical, cartridge or cylinder operated, mild steel shell | every 12 years | Before each hydrostatic test (OSHA) |
| Dry chemical, stainless steel shell | every 5 years | Before each hydrostatic test (OSHA) |
| Carbon dioxide (CO2) | every 5 years | Every 5 years (NFPA 10) |
| Stored pressure water or antifreeze | every 5 years | Antifreeze type: every year (NFPA 10) |
| Cartridge operated water or antifreeze | every 5 years | Before each hydrostatic test (OSHA) |
| Wetting agent | every 5 years | Before each hydrostatic test (OSHA) |
| AFFF foam, or foam in a stainless steel shell | every 5 years | Before each hydrostatic test (OSHA) |
| Loaded stream | every 5 years | Stored pressure type: every year (NFPA 10) |
| Wet chemical (Class K) | every 5 years | Every 5 years (NFPA 10) |
| Halon 1211 | every 12 years | Stored pressure with a 12-year test: emptied every 6 years (NFPA 10) |
| Halon 1301 | every 12 years | Before each hydrostatic test (OSHA) |
| Dry powder, cartridge or cylinder operated, mild steel shell | every 12 years | Before each hydrostatic test (OSHA) |
Put these dates in your calendar
Each date is the first day of the month it falls due, with a reminder 30 days before. The file is made in your browser and nothing is sent. For sprinkler, hood and alarm dates, use the compliance calendar.
Due dates count from the months you enter. A new extinguisher has no test label: ask the service company when its first test falls. A unit with new corrosion or damage is tested before its interval (1910.157(f)(4)).
- Annual tag. NFPA 10 (2010) has the annual tag show the month and year, the person and the company; the monthly check is recorded with its date and the checker's initials on a tag, a checklist or electronically. OSHA requires the annual maintenance date to be recorded.
- Verification-of-service collar. Goes around the neck when the unit is recharged or examined inside.
- Six-year label. A metallic label punched with the month and year. OSHA's rule: stored pressure dry chemical units with a 12-year test are emptied and maintained every 6 years; a recharge or hydrostatic test restarts the clock; disposable units are exempt.
- Hydrostatic test label. Low-pressure shells (dry chemical, wet chemical, water) carry a metallic label with the month, year and test pressure. OSHA also requires a test record with the date, the tester's signature and the serial number.
- CO2 cylinders. High-pressure cylinders are stamped with the tester's identification number and the month and year of the test.
Disposable (nonrechargeable) units are not hydro tested; they leave service 12 years after the date of manufacture. Your state's adopted code can add requirements: see its rules page.
- Intervals and records: OSHA 29 CFR 1910.157(e), (f) and Table L-1, read Oct 15, 2026.
- Tags, labels, collars, internal examinations: Minnesota Department of Health, Maintenance and Testing of Portable Fire Extinguishers (NFPA 10, 2010 edition; rev. June 2024), read Oct 15, 2026.
How often inspectors cite portable fire extinguishers
- US nursing homes cited for portable fire extinguishers (K355), Sep 2023 to Aug 2026
- 2,827 of 14,338 inspected homes (20%)
- Citations of this item
- 3,284 in 30,293 standard inspections
- Rank among all CMS fire safety items, by homes cited
- outside the top 10
- CMS tag text
- K355: Properly select, install, inspect, or maintain portable fire extinguishes.
- Washington55% of 193
- California48% of 1,162
- New Jersey41% of 347
- New Mexico33% of 67
- Maryland27% of 214
- Texas22% of 1,176
- Illinois18% of 666
- Arkansas15% of 221
- New York15% of 578
- Connecticut14% of 188
- Nebraska11% of 180
- Alabama9% of 65
- Utah7% of 97
- Idaho5% of 78
- Oklahoma4% of 282
- United States20% of 14,338
- How counted
- CMS Life Safety Code tags at standard inspections, Sep 2023 to Aug 2026; a home counts once; no home is named
- Nursing home fire safety citations: CMS Fire Safety Deficiencies, release September 30, 2026, downloaded October 8, 2026.
- Inspection dates: CMS Inspection Dates, release September 30, 2026.
- Arkansasnot named
- Oklahoma2010 (guidance)
- Washingtonnot named
- Illinois2022
- Idaho2018
- Alabamanot named
- Nebraskanot named
- Utah2022
- Marylandnot named
- New Yorknot named
- New Mexiconot named
- Texas2018
- Connecticutnot named
- Californianot named
Darker dot: adopted or in licensing rules. Lighter: guidance or exam only. Sources on each state page.
Questions
How often do fire extinguishers need to be inspected?
Every month as a quick visual check, and once a year for a maintenance check. OSHA 29 CFR 1910.157 requires both.
Do I have to recharge a fire extinguisher after using it?
Yes, if it is rechargeable. Recharging is required after every use, even a short one. Dry chemical units often lose pressure slowly after a partial use, so a normal gauge reading right after use does not prove the unit is full.
How often does a fire extinguisher need a hydrostatic test?
Every 5 years for CO2, water, foam, wet chemical and stainless steel dry chemical units, and every 12 years for stored pressure dry chemical and halon units with steel, brass or aluminum shells, per OSHA Table L-1.
Can I throw a fire extinguisher in the trash?
Not if it holds any pressure or agent. A charged or partly used unit is treated as hazardous material. Some places allow a fully emptied unit with the head removed in the trash, and others do not, so check your county.
How often is fire extinguisher training required?
When an employee is hired and at least once a year after that, if the employer provides extinguishers for employee use. Designated extinguisher users need training when assigned and yearly after that.
How far apart should fire extinguishers be?
Close enough that no one walks more than 75 feet to reach one, or 50 feet near flammable liquids, under OSHA 1910.157.
What type of fire extinguisher does a kitchen need?
A Class K wet chemical extinguisher, the type made for commercial kitchen fires in cooking oils and fats.
Never miss your annual fire inspection
Fire extinguishers need maintenance by a licensed company every year (OSHA 29 CFR 1910.157), and sprinkler, alarm and kitchen hood systems have their own schedules. Enter the dates on your last tags and save each next due date to your own calendar, with a reminder before it.
Free. A calendar file you keep; nothing is sent to us. Your fire marshal's notice or your state's adopted code sets the exact dates.